5 Medical Door Features You Should Consider
Apr. 29, 2024
5 Medical Door Features You Should Consider
In our daily work inventory, we keep track of the questions customers ask about medical door products. We found that even though the ways people ask questions are different, they can be summed up in two ways: paying attention to the brand and paying attention to the product, its performance and high standards. Among them, the focus is more on how well the product works and how well it is made.
For more information, please visit aluminum cleanroom door.
The medical door features like airtightness, crash resistance, durability, and after-sales service have become the most aspects when looking for durability and performance. They are the most important things that customers use to decide whether or not to buy.
When looking online for a medical door that is either sliding glass door or a aluminum glass door, it is important to understand the quality, finishing and durability as the key aspects. Making sure the material meet the demands of medical precaution tests and also that the door can air tightly close from all the sides.
1 - The Guarantee Of Airtightness Of The Medical Door
As far as the general ward door is concerned, the airtightness of the door body can be ensured through the following aspects.
First of all, it is necessary to ensure that the glass window on the door of the ward and the door leaf are flush and integrated, and the height of the surrounding frame is multiple sealed to ensure that there is no oxygen inside the window to cause the window to condense.
The second is to use high-quality and high-elasticity silicone strips for sealing around the door frame. So as to achieve the effect of efficiently isolating the air from inside and outside when the door is closed.
The third is to install lifting sweeping strips at the bottom of the door leaf. When the door is lifted, it rises smoothly, and the door is closed and descends smoothly to reduce the secondary air pollution caused by the opening and closing of the door.
2 - The Structure Of A Medical/Hospital Door
Finally, considering the whole door structure, it is necessary to ensure that the door body is flush during installation, so that the door frame and the door leaf are in the best matching position, which can not only average the force of the hinge, prolong the life of the hinge, but also make better use of the silicone strip. The elastic performance of the rubber strip can slow down the aging process of the rubber strip.
Compared with ordinary ward doors, patient room door, operating room doors have stricter air tightness control. Therefore, in the overall structure, the door of the operating room adopts the integrated design of the door frame and the anti-balance wheel. The opening and closing operation is more stable, and a slight thrust is applied to achieve a high degree of airtightness when closing. If you want to further enhance the air tightness, you can also configure the function of sinking inner buckle to better isolate the air and hinder the further flow of air.
3 - How is the anti-collision performance of the medical door reflected?
The choice of panel materials is the best way to show how safe a car is in a crash. Most medical door fabrics on the market are made of steel, color steel plate, special board that doesn't fold, or resin fireproof board. The impact resistance of all-steel doors and color steel plates is better than that of antibacterial boards with good silver ion bacteriostatic and resin panels with higher fire resistance.
The anti-collision performance is also shown by the choice of PU and paper honeycomb for the door body filling core. Honeycombs made of aluminum can be used as fillers in medical doors. But PU and paper honeycomb don't stand up well to fire, and burning PU makes toxic gas. Paper honeycomb also doesn't stand up well to water and moisture, so it's usually not a good idea. Aluminum honeycomb, on the other hand, can reach a fire rating of A1 and is resistant to moisture and corrosion. It can also stand up well to the weather and last for a long time.
4 - How to maintain the cleanliness of the medical door?
The use of medical doors, especially the selection of categories in hospitals, cleanliness is the first point of concern. Since there are many functional areas within the hospital, there are many types of hospital doors. Most hospital doors choose products with cleaning function or easy cleaning on the panel and hardware materials. Which can inhibit the reproduction and growth of bacteria to a certain extent and hinder their rapid spread.
Different types of hospital doors have some unique clean designs, such as the openable door frame design of the operating room door. Which can be opened at any time during cleaning without leaving a dead corner and no dust accumulation; the escape door adopts a push-down escape lock design, and the lock body has a simple structure. It is not easy to accumulate dust and is convenient to clean. Pressing the door to open the door conforms to the human body's instinctive escape gesture, which is clean and safe.
5 - ICU Door and Emergency Rooms Door Minimum Standards
When it comes to the ICU Doors and the emergency rooms door the standards and demands become more crucial. The quality can not be compromised, the environment should be highly maintained and of course there should be no compromise on the cleanness of the door.
When ordering ICU doors or emergency rooms door always make sure the doors are air tightened so there is no unnecessary gap on any sides. Make sure the quality of material is high so that it can be use safely in the intensive care units. Also the coating on a door should be antibacterial.
What You Need to Know When Considering a Cleanroom
There are numerous considerations when evaluating a cleanroom.
Does your business plan include the development of an area in your plant for clean manufacturing? Are you concerned that you make the right purchase? Do you want to make sure you consider the right factors when you evaluate different models?
There are numerous considerations when evaluating a cleanroom. This article covers the basics.
You may very well need to employ the services of a cleanroom consultant to help you. Here are a few things to keep in mind as you start to consider cleanrooms and controlled environments.
1. What’s the application?
Better quality or better yield is the primary reason for investing in a cleanroom space. It goes straight to your bottom line.
Numerous manufacturing procedures now require a controlled environment in which you limit the amount of dust and dirt in the area of the manufacturing. Medical instrument manufacturing and packaging, electronics and computer manufacturing, food preparation and some military applications are but a few of the instances that have strict requirements for maintaining a clean environment. You need to know the requirement for your specific product or process. If the product you are manufacturing is regulated by a government agency, or you are contracting with a private firm that requires a certain level of clean manufacturing, they should have the cleanroom standards already documented. Check with them first.
There are different levels of cleanrooms. ISO—the International Standards Organization, ranks cleanrooms ISO Class 1 (the cleanest) through ISO Class 9. The lower the ISO rating, the cleaner the environment.
There are different levels of cleanrooms. ISO—the International Standards Organization, ranks cleanrooms ISO Class 1 (the cleanest) through ISO Class 9. The lower the ISO rating, the cleaner the environment. Measurement of contamination is done in “parts-per-cubic-meter.” An ISO Class 6 cleanroom, for example, is rated at 35,200 parts per cubic meter. That means the room can have no more than 35,200 particles greater than .5 micron in size per cubic meter. These are particles that are not visible to the human eye. (As a comparison, a particle of cigarette smoke is between .5 and 2 micron in size. The end of a piece of human hair is about 60 to 100 microns in size).
Particle counts are performed at the work surface height. The pre-filters remove the dirt and dust you can see (call them baseballs and boulders). HEPA filters capture the particles you can’t see with a human eye. A light manufacturing area (defined as an environment that is not generating smoke or oil mist, such as storm window assembly and packaging) with pre-filtration on a HVAC system might be equivalent to an ISO Class 8 room, with 3,520,000 parts per cubic meter that measure greater than .5 micron. This is comparable to room air.
Again, know what the manufacturing requirements are.
2. Know the basic principles behind how a cleanroom works
The majority of cleanrooms, easily more than 90%, are positive-pressure rooms—designed to keep contaminants from entering the room. Air is introduced into the cleanroom, typically at the ceiling level, after passing through a fan-powered HEPA filter that removes particles as small as .5 microns. This creates a pressurized room in which the air pressure in the room is greater than outside the room— hence, positive pressure. The air, and the contaminants in the air, are then pushed down towards the floors, and ultimately pushed out vents in the lower portions of the walls of the room.
This means that air and contaminants from the processes in the room are constantly flowing out of the room. In addition, the air exiting the room, either through vents or when doors are opened, is at a pressure sufficient enough to prevent contaminants from entering via those openings.
Negative-pressure rooms are designed to keep contaminants from leaving the room. A negative pressure room is used in instances of infectious diseases and pathogens, bio-contaminants and some hazardous processes using chemicals, flammables and potentially explosive liquids and powders. Your concern is not what gets into the room, but what gets out.
In a negative pressure room, air is pulled out of the enclosure through reversed HEPA filters, creating a negative pressure inside the room (which prevents contaminants from leaving the room), while air is constantly being drawn in through venting and other openings. The force of the air entering the room prevents contaminants from escaping.
Because they are so prevalent, for purposes of this white paper we will be discussing positive-pressure rooms.
3. ISO standards are the industry norm for rating cleanrooms.
ISO standards were adopted by the industry in 2001. If you do any serious research into ISO standards, you are likely to come across the Federal Standard 209E for cleanrooms, which was the industry norm until ISO standards were developed. The federal standards were officially cancelled by the US Department of Commerce in November 2001, but they are still widely referenced.
“ISO classifications expanded the horizon for classifying clean space,” according to Richard Matthews of Filtration Technology, Inc., in Greensboro, NC, who chaired the ISO board that developed these standards. Here are the Federal standards and their ISO equivalents. Note that ISO created three new levels that the Federal standard did not address.
ISO Class 9 = No comparable Federal standard
If you are looking for more details, kindly visit bed head unit price.
ISO Class 8 = Federal standard Class 100,000
ISO Class 7 = Federal standard Class 10,000
ISO Class 6 = Federal standard Class 1,000
ISO Class 5 = Federal standard Class 100
ISO Class 4 = Federal standard Class 10
ISO Class 3 = Federal Standard Class 1
ISO Class 2 = No comparable Federal standard
ISO Class 1 = No comparable Federal standard
Whenever possible, refer to the ISO standards because they are internationally accepted. If you are dealing with partners in other countries, this will make issues much simpler.
4. It’s all about air changes per hour, sometimes
With some exceptions, a cleanroom is a cleanroom is a cleanroom. Achieving a cleaner class of cleanroom is all about airflow. It’s a matter of bringing clean air in through HEPA filters in the ceiling and moving contaminated air out through vents in the walls or floors. The greater the number of HEPA filters and vents, the greater the rate of air change. You can see from this chart what the requirements are:
ISO Class 9 through ISO Class 6 rooms are determined based on air changes per hour. ISO Class 5 through ISO Class 1 rooms are based on the flow of air through the room in meters per second. How are you getting the air into the space and how are you pushng it out? It’s easy to clean the air. The more difficult question is: Are you moving the air out of the area properly? Where does air enter the clean space and how conveniently is it moved out, carrying with it the contaminants from the manufacturing process? Placement of work tables, chairs and equipment becomes more crucial. An item incorrectly placed creates “dead space” where particles are trapped.
These environments are prevalent in micro-electronics and will play a big part in nanotechnology as we get more involved in that industry. At these levels it is very important that you consult with a knowledgeable expert.
5. Every cleanroom has three different states or conditions
Cleanrooms are measured for particulate count at three different levels: As Built, At Rest and Operational. As Built refers to the cleanroom as it is when it is built, empty of any equipment, materials or workers. Cleanrooms are typically certified by the manufacturer as to their level of cleanliness at the As Built level. At Rest refers to the cleanroom once equipment, machinery, furniture and product have been moved in, before the workers. All these elements bring with them sources of contamination, so you can expect a change in particulate count. Finally, there is the Operational level. This refers to the cleanroom when all the equipment and materials are moved in and there are workers in there performing tasks. Again, you are likely to see a change in particulate count. Machinery that performs an excellent function outside of a cleanroom can be a source of pollution inside a cleanroom. Metal shavings, gases and oil mist from pneumatic machinery and vapors from outgassing plastics are all sources of contamination.
Any process that involves friction or movement is going to cause particulation. In order to prevent a drastic increase in contamination at the operational level it is important to adhere to proper protocol and procedures—things like gowning, house cleaning and workflow. If your process must involve machinery, then it may be necessary to further isolate that machine within the cleanroom in order to prevent it from contaminating the rest of the operation. A common solution is to build a cleanroom within the cleanroom using either partitions, or more commonly curtains, to isolate the machine. It may also be necessary to vent that area separately from the rest of the room.
This change in particulate count from As Built, At Rest and Operational levels is another reason that you need to involve a cleanroom expert early on in the process.
6. Modularity
Things change. You can count on that. A cleanroom with a modular design allows the original layout to be expanded without having to rebuild from scratch. Your need for clean manufacturing space will increase or expansion will dictate that you move to larger facilities. Modularity in a cleanroom is important. With a modular design you can, with ease, expand the size of your cleanroom as your needs increase, without having to toss out part or all of your original cleanroom investment. And in the event you move to a new facility, you can disassemble your modular cleanroom and take it with you.
There are also cleanroom designs that incorporate casters so that the enclosure can be easily moved around your factory floor. An example where this might be applicable is an injection mold facility where the manufacturing area is ISO Class 9, but production has an order for an I.V. component that requires an ISO Class 7 environment (an I.V. system has to be manufactured in at least an ISO Class 7 cleanroom). You can create this environment on the factory floor by enclosing the injection-mold machine in a portable cleanroom outfitted with casters and a HEPA unit installed in the ceiling grid. Simply roll the enclosure to the appropriate machine and attach softwall curtains to contain it.
Another advantage to a modular cleanroom is in its tax benefits. A modular cleanroom can be written off in seven years. An existing room within your facility that is transformed into a cleanroom—referred to as “stick-built”—has to be written off over a much longer period of time.
7. Envision future plans
Don’t make the mistake of trying to get along with a minimum of cleanroom space. You will be surprised at the speed your cleanroom needs increase. Better to plan for too much space than not enough.
8. Don’t underestimate air conditioning needs
You might start with three workers in your cleanroom, and then find you need to increase to five or six. All that extra body heat, as well as any heat-producing machinery in your clean area, and that cleanroom quickly starts getting hot and uncomfortable. Also take into consideration that basic cleanroom clothing includes a hair covering, booties and a smock. Anything cleaner than Class 7 requires additional safeguards—masks, beard covers, goggles, etc. It is better to err on the side of too much when planning for air conditioning.
This is where you get into the difference between single-pass and recirculating rooms. A single-pass room is a simple design in which air is pumped into the room from the top and blown out vents at the bottom. If you have to air condition your cleanroom, then you don’t want to just blow that expensive air-conditioned air through the cleanroom and out into a warehouse or other environment where it does little good. A recirculating design uses a double-ceiling system (the space between the ceilings is called a plenum) or a double wall (the space in the walls is called an air chase), or a combination of these two. Cooled, clean air is introduced through the HEPA filters and then flows out of the room, carrying with it any contaminants, into either the air chase or the ceiling plenum, where it is reintroduced into the room after once again passing through the HEPA filters.
When you plan and budget for your cleanroom, consider that installation of a recirculating system for that enclosure is going to be at least 50% of the installation costs. If it is possible to place the cleanroom in an area where air conditioning is already in place that will be a huge money-saver.
9. Not considering all that is needed
It pays to bring in an expert early in the planning process. They can help you troubleshoot airflow problems, the types of testing procedures you must employ, and how to develop cleanroom protocols. A knowledgeable professional will point out things you will not even consider.
It pays to bring in an expert early in the planning process. A knowledgeable professional will point out things you will not even consider
10. Think about process flow
Give some thought to the workflow in your cleanroom. You want materials to come in one end and exit the other, and in the meantime, completing all the necessary assembly and packaging that is needed. The goal is not only to improve productivity and yield but to maintain or improve the speed of the manufacturing process. Again, this is an area where you should employ a consultant.
11. The need for interior isolation.
Every cleanroom ISO Class 7 or cleaner should have an anteroom for gowning, set off from the larger cleanroom with softwall curtains at least. This keeps street dirt from getting into the clean area. Interior isolation is also important in food processing and pharmaceuticals to prevent cross-contamination. A recent Simplex project called for dividers for a vitamin processing operation. If vitamin B12 meanders into the Vitamin C work area, that’s cross-contamination—a huge problem. Cross-contamination can mean manufacturing shutdowns and product recalls and lost profits.
12. Clearance issues
People are often eager to use as much of their space as possible. It is a good idea to give yourself some extra room overhead between the outside ceiling of your cleanroom and the ceiling of your building—Simplex recommends three feet—to allow you to change out the pre-filters, HEPA’s and ULPA’s without a big hassle. The other issue to consider is that without enough clearance, a minimum of six inches, you run the risk of starving your filters for air.
13. More need for clearance
Regarding installation of the room itself, three feet is important all the way around the side walls. It will make the installation easier, as you will have more room to work with. The common space solution is to place the cleanroom against the walls and this is often done. This is great for maximizing the footprint but will make the install more difficult.
The performance of your cleanroom hinges a great deal on the quality of the assembly. Look for a company that supplies the approval drawings with layout and elevations, and also shows the HEPA and lighting layout.
14. Look for a cleanroom with extensive plans and instructions
The performance of your cleanroom hinges a great deal on the quality of the assembly. Look for a company that supplies the approval drawings with layout and elevations, and also shows the HEPA and lighting layout. Look for a manufacturer that supplies installation drawings with every panel marked with a letter or number that corresponds to the panel or part on the drawing. For large cleanrooms and critical applications you might need to consider a specialty contractor knowledgeable in cleanroom construction.
15. Know the difference between a cleanroom and a clean zone and be clear in what you need
Cleanrooms are areas in which the particulate count is measured and controlled. There is a requirement for a specific level of clean. A clean zone is an area within an existing cleanroom that is even cleaner, much like the injection mold operation cited in #4.
There are also areas that a manufacturer may want to isolate, but not have to maintain at a certain ISO level. A recent project Simplex completed involved a manufacturing and warehousing facility where inventory was stored adjacent to the manufacturing area. Dust from the manufacturing process was drifting into the storage area. Although the product was not required to be clean when it was shipped, the manufacturer wanted it to be free from excessive dust—for aesthetic reasons. The goal in this case was isolation, not making the environment clean in the sense of a cleanroom. Simplex installed 300 running feet of industrial opaque vinyl curtain and two industrial strip doors that created a clean zone where product could be stored. Inventory could be shipped without the need for a second cleaning.
16. Establish cleanroom operating procedures and have them documented
Make sure your employees read them, are familiar with them, and follow them—always. The single biggest source of contamination in a clean area is—you guessed it—the worker in that area. If your cleanroom requirements call for gowning and booties, then no employee should ever enter that space without them. To do otherwise contaminates your workplace and sacrifices the integrity of your manufacturing process.
NOTE: Maintaining clean environments can be a complicated and critical task. The information provided here is meant to give the reader a basic understanding of the issues involving the selection of a cleanroom. Simplex recommends that you always consult and work with a cleanroom professional when implementing any sort of isolation procedures in your workplace, laboratory or hospital, thus ensuring that you maintain the highest standards.
Simplex Isolation Systems wishes to thank Richard Matthews of Filtration Technology, Inc., in Greensboro, NC, for his input on this white paper.
Want more information on bed head units manufacturers? Feel free to contact us.
55