What is single-suction pipeline centrifugal pumps and Why Do We Use Them?
Picking a Centrifugal Pump: Choosing Single or Double Suction
Last week, the R. L. Deppmann Monday Morning Minutes described the differences between flex coupled HVAC pumps, split coupled pumps, and direct-coupled pumps. If the engineer decides to accept the owner benefits of a flexibly coupled pump, they may be faced with the choice of single or double suction. What are the differences between a single and double suction pump and what advantages does one have over the other? Thats what we are exploring this week.
You can find more information on our web, so please take a look.
Double Suction HVAC Centrifugal Pump Benefits
In a single suction centrifugal pump, water flows into the pump inlet and 100% of the liquid immediately flows into the eye or inlet of the impeller. The centrifugal action then creates pressure as the water exits the impeller through the veins. The central difference between a single and double suction pump is the latter has an impeller designed to draw flow through it from both sides. This double suction design splits the flow inside of the pump and sends 50% of the water through two eyes. This splitting or double suction design eliminates the axial forces on the impeller which allows for higher flows than single suction pumps.
The following is a screenshot from the Bell and Gossett online e-training program available for your use. If you have not viewed the B&G Little Red Schoolhouse Online classes, it may be worth a look.
Since the flow is split into two directions and the axial forces are balanced, double suction pumps are also less vulnerable to wear and tear. Since water enters both sides of a double suction impeller, one side effectively cancels out the axial thrust of the other. The pump still requires bearings for the shaft to ride on, and double suction pumps have inboard and outboard bearings to absorb the radial load. However, these bearings can afford to be smaller than single suction pumps simply because there is better balance across the shaft of a double suction pump.
Double Suction HVAC Centrifugal Pump Applications
We typically recommend a double suction pump design for HVAC applications around 2,000 GPM or an 8 pump size. When it comes to applying a double suction pump we adhere to a couple of recommendations:
Select a pump with the shortest shaft span possible to minimize shaft deflections.
Specify base-mounted pumps with flexible couplers whenever possible. These pumps are easier to service than double suction inline pumps, which require the motor to be removed for replacement of throttle bushings which periodically wear out.
Generally speaking, a double suction base mounted pumps can be twice the cost of a comparable single suction base mounted design. On the other hand, double suction pumps last longer. In HVAC applications, double suction pumps typically last as long as 30 to 40 years. This is the pump to use when your client expects to own the building for a long time and repair staff is at a premium.
Types of Double Suction HVAC Centrifugal Pumps
When it comes to selecting a base mounted double suction pump, there are 3 configurations to choose from, including:
Horizontal Split Case
These pumps have a clam shell type volute that is split horizontally across. The top part of the volute is bolted to the bottom. This design is definitely old school. It has been around for close to 100 years. Because the pump is split horizontally, there is significantly more service time and rigging required to lift the heavy top of the pump. Watch for very old specifications. Many people called double suction pumps split case, all of these pumps have split casings. It just depends on whether the case is split horizontally or vertically.
Vertical Split Case
Vertical split case pumps are split vertically with removable cover plates on the end that can be removed to service the bearings, seals, impeller, or pump shaft. Here is a shot from the Bell and Gossett service video.
Vertical split case pumps come in 3 different configurations as shown here, that can save floor space depending on the building piping configuration requirements:
If you are looking for more details, kindly visit SHANGLISHI.
Double Suction Inline
These pumps can be quite large and are typically double suction when the pump gets over 12 piping flange size.
Double suction inline pumps have bushings instead of bearings, which should be inspected whenever the pump seal is serviced. Normally this inspection occurs frequently with this style of pump, as they are susceptible to wear and tear. This is significant because the motor of these pumps must be lifted off the top to change out the bushings, or to service the pump seals.
Vertical Split Case vs. Horizontal Split Case Pump
A very good case can be made for choosing a vertical split case pump over a horizontal split case pump. First, vertically split case pumps can and often do take up far less space, depending on the orientation of the pipe connections. Assuming the suction and discharge piping can be vertical, its easy to see from the following diagram why this is so:
Second, the shorter distance between the bearings on a vertical split case pump helps reduce shaft deflection and thus helps lengthen the life of the pump:
Whats the takeaway of all this? When higher capacities are required, double-suction pumps can be a long-lasting solution. Double suction pumps come in a variety of configurations to accommodate various piping connections. Vertical split case double suction pumps are more space efficient than horizontal split case double suction pumps especially when the discharge and suction piping comes vertically from above. Double suction inline pumps are also an option, but are only available in very large sizes. The weight of the motors (which must be lifted away) makes servicing these pumps problematic.
Check out Part 6 where we talk about pump seals!
Read the Entire How to Pick an HVAC Centrifugal Pump series:
Single suction pump vs double suction pump
Today we will discuss what is the difference between a single suction pump and a double suction pump in a centrifugal pump that people often wonder about
Single suction pump
The single suction pump also called end suction pump, the basic parts of single suction pump are high speed rotating impeller and fixed worm-shaped pump casing. The impeller with several (usually 4~12) backward curved vanes is fixed on the pump shaft and driven by the motor to rotate the pump shaft at high speed. The impeller is a direct part of the pump to do work on the liquid in the pump, and is the energy supply device of the centrifugal pump. The suction port in the center of the pump casing is connected to the suction pipe, which is equipped with a one-way bottom valve at the bottom. The discharge outlet on the pump casing side is connected to the discharge pipe with a regulating valve.
The single suction pump has the advantages of smooth operation, simple structure, easy maintenance and repair, convenient installation and less land occupation. Single suction pump has low cost, reasonable price and wide application. Single suction pump flow is smaller, the flow is equal, the volume of single suction pump is smaller, but the axial force is large, the bearing load is large.
Double suction pump
Double suction pump actually consists of two back-to-back impellers, the water flowing from the impeller converges into a worm gear equivalent to two single-suction impellers of the same diameter working at the same time, in the case of the same impeller outer diameter, the flow can be doubled; the advantage of double suction pump is that, at the same speed and flow, cavitation is less likely to occur due to the reduction of inlet flow
Difference between single suction and double suction pump
The main difference between double-suction and single suction pumps is the impeller. The single suction impeller is single-sided suction, and the front and back covers of the impeller are asymmetrical. The double suction impeller is sucking water on both sides, and the impeller cover is symmetrical
single suction pump impellerdouble suction pump impellerA single suction pump is one where only one end of the impeller feeds water, a double suction pump is one where both ends of the impeller feed water, with two inlets
Double-suction pump is more suitable for conveying a large flow rate and requires smooth running conditions. When the pump flow requirements are very high, if the pump is a single-suction pump is to have a large pump inlet and outlet caliber, at the same time, the speed can not be too large, need to stabilize at about rmp. If the double-suction pump is used, the size and weight of the pump can be relatively reduced, the rotational speed can also be increased, and the volumetric efficiency increased
Double suction pump has stronger anti-cavitation ability than single suction pump. As the medium is sucked in at both ends of the impeller, it will form hydraulic symmetry, so that the double-suction pump can balance the axial thrust effect better than the single-suction pump and run more smoothly. And the flow rate of the medium is low, the impeller is not easy to produce cavitation phenomenon
The cost of single suction pump is lower than double suction pump, end suction pump is a kind of pump commonly used in agriculture, double suction pump is mainly used in mines, cities, power stations, water supply and drainage of various water conservancy projects. The specific decision should be made according to the actual operating conditions of the user.
Need help selecting the right double suction pump for your application?
Contact us at or +86 ;
Our technical sales engineers have the extensive product knowledge and will be able to help you.
For more single-suction pipeline centrifugal pumpsinformation, please contact us. We will provide professional answers.
33
0
0
Comments